Guangzhou Sunning Wind Power Generator Co., Ltd.
Main products:Wind Turbine,Street Light,Solar Panel,Controller,Inverter
Products
Contact Us
  • Contact Person : Ms. Wong Christine
  • Company Name : Guangzhou Sunning Wind Power Generator Co., Ltd.
  • Tel : 86-020-39211683
  • Fax : 86-020-39388854
  • Address : Guangdong,Guangzhou,Room 305-306, Hi-Tech Exchange Center, Tian An Hi-Tech Ecological Park, 555 Panyu Avenue North.Panyu District,Guangzhou, China
  • Country/Region : China
  • Zip : 511400

Pure Sine Wave Inverter For Wind Solar System 1000W 48V

Pure Sine Wave Inverter For Wind Solar System 1000W 48V
Product Detailed
Pure Sine Wave Inverter For Wind Solar System 1000W 48V,Output Frequency 50Hz/60Hz,Maximum efficiency >90%,Power factor >99%

1.Performance Specification of Intelligent inverter1.The inverter is designed by our company independently; it's controlled by CPU, high quality and modify sine wave intelligent inverter2.Our product is used for the many kinds of the single phase equipments, example: motor, screw tools,tube light etc.family equipments, and also it can be used for the industry and communication equipments.3.Single key intelligent switching, easy to operated4.Output short circuit protection (when the inverter is working on battery mode): when there is short circuit, the inverter will indicate it and the machine will shut down automatically.5.Overload protection: when there is overload, the machine will prompt you and protect the inverter from being damaged automatically. Over 100%-120%, inverter shuts down 30s later, over 150%, inverter shuts down at once.6.Internal circuit can protect the battery .when the battery voltage is under the 15% level,the inverter will be shut down at once.

Warnning :A.If not allowed by our company, this device can't supply power for the equipments which maintain the life B.This products is designed to supply the reserve inverted power for the home electric appliances, so it's not fit for the precision equipmentsC.If it is used for the computer, the computer must have a enough power inside. Or the computer maybe is restarted, when the city power is interrupted.2. Use range of Intelligent inverterit can be used for t family equipments, and also the industry and communication equipments.3. Installation Guides for inverter (1)1000W power output and the following connections using the form of Multi-outlet, DC input lead straight out of the use of connected(2)1000W power output over using the form of Multi-outlet and output terminal block , DC input terminal station used to connect(3)Multi-outlet can load less than 10A220VAC equipments.4 Inverter Technical Specifications

Model SN-0.5K24V-220ZSN-1K48V-220ZSN-1.5K48V-220ZSN-2K48V-220Z
Output PowerPower

500W

1000W

1500W

2000W

DC voltage

Maximum rated power (VA)

550VA

1100VA

1650VA

2200VA

 

Range of input(VDC)

21-28V

42-58V

42-58V

42-58V

Rated voltage of chargeable battery

24V

48V

48V

48V

Output Power

Rated Output Power (W)

500W

1000W

1500W

2000W

 

Output Frequency(Hz)

50Hz/60Hz

Output rated current(A)

2.3A

4.6A

6.8A

9A

Inverter output voltage(V)

220V/110V

(THD)

THD<3%

Maximum rated power(W)

550W

1100W

1650W

2200W

Maximum efficiency

>90%

Power factor

>99%

Input reverse polarity protectionpositive electrode series insurance burned
fuse specifications

25A*2

Low - voltage alarmInput voltage drops below the set limits, the indicator light flashing alarm and turn off the inverter

Hight- voltage alarm

Input voltage is higher than the set limits, lights flashing alarm input voltage higher than the set limits, lights flashing alarm

Voltage protection

The input voltage is above or below the set limits the inverter will stop work

overload protecting

20% of the load exceeds the rated load, the inverter is turned off

short circuit protecting

Inverter when the output short circuit shut down the system automatically restart in one minute, three failed to start, then shut down the system, need to re-open the power switch
Over TemperatureTemperature exceeds 70 ° C is automatically enabled cooling fan, more than 80 °C to turn off the inverter system. Temperature is below 60 °C automatically restart
Fault informationload faultsRed light alarm LCD display specific fault information

4Mains input

Power

500W

\1000W

1500W

2000W

Mains input voltage

110V/220V

Input Frequency(MHz)

60HZ/50HZ

Mains input current

2.3A

4.6A

6.8A

9A

Transfer time

10ms

5. Environment and safety

Isolate Level(DC/AC)

1500V/1minute

Operating temperature

-20°C~+45°C

Transport/storage temperature

-20°C~+75°C

Operating humidity

0~95%R.H.

Operating altitude

3000m

Protection grade

IP22

Safety

LVD EN60950-1

Safety

≤10ms

Interface

RS232

Quality certification

CE

 