1.Performance Specification of Intelligent inverter1.The inverter is designed by our company independently; it's controlled by CPU, high quality and modify sine wave intelligent inverter2.Our product is used for the many kinds of the single phase equipments, example: motor, screw tools,tube light etc.family equipments, and also it can be used for the industry and communication equipments.3.Single key intelligent switching, easy to operated4.Output short circuit protection (when the inverter is working on battery mode): when there is short circuit, the inverter will indicate it and the machine will shut down automatically.5.Overload protection: when there is overload, the machine will prompt you and protect the inverter from being damaged automatically. Over 100%-120%, inverter shuts down 30s later, over 150%, inverter shuts down at once.6.Internal circuit can protect the battery .when the battery voltage is under the 15% level,the inverter will be shut down at once.
Warnning :A.If not allowed by our company, this device can't supply power for the equipments which maintain the life B.This products is designed to supply the reserve inverted power for the home electric appliances, so it's not fit for the precision equipmentsC.If it is used for the computer, the computer must have a enough power inside. Or the computer maybe is restarted, when the city power is interrupted.2. Use range of Intelligent inverterit can be used for t family equipments, and also the industry and communication equipments.3. Installation Guides for inverter (1)1000W power output and the following connections using the form of Multi-outlet, DC input lead straight out of the use of connected(2)1000W power output over using the form of Multi-outlet and output terminal block , DC input terminal station used to connect(3)Multi-outlet can load less than 10A220VAC equipments.4 Inverter Technical Specifications
Model | SN-0.5K24V-220Z | SN-1K48V-220Z | SN-1.5K48V-220Z | SN-2K48V-220Z | |
Output Power | Power | 500W | 1000W | 1500W | 2000W |
DC voltage | Maximum rated power (VA) | 550VA | 1100VA | 1650VA | 2200VA |
Range of input(VDC) | 21-28V | 42-58V | 42-58V | 42-58V | |
Rated voltage of chargeable battery | 24V | 48V | 48V | 48V | |
Output Power | Rated Output Power (W) | 500W | 1000W | 1500W | 2000W |
Output Frequency(Hz) | 50Hz/60Hz | ||||
Output rated current(A) | 2.3A | 4.6A | 6.8A | 9A | |
Inverter output voltage(V) | 220V/110V | ||||
(THD) | THD<3% | ||||
Maximum rated power(W) | 550W | 1100W | 1650W | 2200W | |
Maximum efficiency | >90% | ||||
Power factor | >99% | ||||
Input reverse polarity protection | positive electrode series insurance burned | ||||
fuse specifications | 25A*2 | ||||
Low - voltage alarm | Input voltage drops below the set limits, the indicator light flashing alarm and turn off the inverter | ||||
Hight- voltage alarm | Input voltage is higher than the set limits, lights flashing alarm input voltage higher than the set limits, lights flashing alarm | ||||
Voltage protection | The input voltage is above or below the set limits the inverter will stop work | ||||
overload protecting | 20% of the load exceeds the rated load, the inverter is turned off | ||||
short circuit protecting | Inverter when the output short circuit shut down the system automatically restart in one minute, three failed to start, then shut down the system, need to re-open the power switch | ||||
Over Temperature | Temperature exceeds 70 ° C is automatically enabled cooling fan, more than 80 °C to turn off the inverter system. Temperature is below 60 °C automatically restart | ||||
Fault information | load faults | Red light alarm LCD display specific fault information |
4Mains input
Power | 500W | \1000W | 1500W | 2000W |
Mains input voltage | 110V/220V | |||
Input Frequency(MHz) | 60HZ/50HZ | |||
Mains input current | 2.3A | 4.6A | 6.8A | 9A |
Transfer time | 10ms |
5. Environment and safety
Isolate Level(DC/AC) | 1500V/1minute |
Operating temperature | -20°C~+45°C |
Transport/storage temperature | -20°C~+75°C |
Operating humidity | 0~95%R.H. |
Operating altitude | 3000m |
Protection grade | IP22 |
Safety | LVD EN60950-1 |
Safety | ≤10ms |
Interface | RS232 |
Quality certification | CE |